Bayville Chemical Supply Company Inc 70-G East Jefryn Boulevard Deer Park, New York, 11729 USA Telephone: 631-586-4309 Fax: 631-254-5591 E-Mail: info@bayvillechemical.net
Bayville Chemical Supply Company Inc70-G East Jefryn BoulevardDeer Park, New York, 11729  USA           Telephone: 631-586-4309      Fax: 631-254-5591      E-Mail: info@bayvillechemical.net

 

 

Nitrogen Trifluoride

 

NF3

 

Nitrogen Trifluoride gas is toxic, stable and colorless. It has a musty, moldy odor at room temperature and pressure. It is shipped as a nonliquified gas in steel cylinders at a pressure of 200 psig at 21.0oC.

 

Applications:

NF3 is used in the preparation of tetrafluorohydrazine, for fluorination of fluorocarbon olefins and as an oxidizer of high energy fuels.

 

Technical Data:

Formula

NF3

Molecular Weight

71.001

Absolute Density (Gas)

2.96 kg/m3 (@101.325 kPa@20oC)

Relative Density (Gas) (air=1)

2.46(@101.325 kPa@20oC)

Density (Liquid)

1.531 kg/l (@-129.0oC)

Boiling Point

-129.0oC (@101.325 kPa)

 

Typical Analysis:

Assay

99%

99.5%

99.9%

>99.99%

 

 

 

 

 

Carbon Dioxide

50 ppm

25 ppm

10 ppm

<2ppm

Carbon Monoxide

50 ppm

25 ppm

10 ppm

<0.1 ppm

Dew Point

-86oF

-105oF

-106oF

 -105oF

Nitrogen

3000 ppm

700 ppm

50 ppm

  1 ppm

Nitrous Oxide

200 ppm

50 ppm

10 ppm

<1 ppm

Sulfur Hexafluoride

200 ppm

50 ppm

50 ppm

< 0.1 ppm

Tetrafluoromethane

5000 ppm

1500 ppm

700 ppm

 25 ppm

Water

5 ppm

1 ppm

1 ppm

<1 ppm

Oxygen & Argon

5000 ppm

700 ppm

50 ppm

  1 ppm

Total Fluorides (as HF)

N/A

0.3 ppm

0.3 ppm

<1 ppm

 

GHS-US labeling

Hazard pictograms (GHS-US):   

Signal word (GHS-US):                DANGER

Hazard statements (GHS-US):   

H270 - MAY CAUSE OR INTENSIFY FIRE; OXIDIZER

H280 - CONTAINS GAS UNDER PRESSURE; MAY EXPLODE IF HEATED

H332 - HARMFUL IF INHALED H373 - MAY CAUSE DAMAGE TO ORGANS (BLOOD, CIRCULATORY SYSTEM) THROUGH PROLONGED OR REPEATED EXPOSURE

 

Precautionary statements (GHS-US):                                                 

P202 - Do not handle until all safety precautions have been read and understood

P220 - Keep/Store away from clothing, combustible materials

P244 - Keep reduction valves/valves and fittings free from oil and grease P260 - Do not breathe Gas

P271+P403 - Use and store only outdoors or in a well-ventilated place. P370+P376 - In case of fire: Stop leak if safe to do so

CGA-PG05 - Use a back flow preventive device in the piping.

CGA-PG20+CGA-PG10 - Use only with equipment of compatible materials of construction and rated for cylinder pressure.

CGA-PG22 - Use only with equipment cleaned for oxygen service.

CGA-PG21 - Open valve slowly.

CGA-PG06 - Close valve after each use and when empty.

CGA-PG02 - Protect from sunlight when ambient temperature exceeds 52°C (125°F).

 

Other hazards

Other hazards not contributing to the classification: Contact with liquid may cause cold burns/frostbite.

Where to Find Us:

Bayville Chemical
70 East Jefryn Boulevard
Suite G
Deer Park, NY 11729


Phone: 631 586-4309

What's New

New larger location

As of August 2014, we have moved to this new, larger, modern facility to better service your needs.

 



Like us on Facebook .

PrintPrint | Sitemap